Material Leakage Factors Of Mixer

P11SDPM Series Double Shaft Paddle Type Mixer2P12SSPM Series Single Shaft Paddle Type Mixer

1.Reason: The sealing strip is not tightly sealed

Solution: Readjust or reinstall

2.Reason: The sealing strip is damaged

Treatment method: replace the sealing strip

3.Reason: Material accumulation on one side of the discharge door

Solution: Clean up the accumulated material

4.Reason: Insufficient cylinder pressure

Solution: Adjust pressure ≥0.63MPa

5.Reason: The connection body of the discharging door linkage mechanism is worn

Solution: Replace related wear parts

6.Reason: The position of the travel switch is wrong (electric)

Solution: Adjust the position of the travel switch

7.Reason: Displacement of the discharge door

Solution: Adjust and fix

8.Cause: Strut Shift

Solution: Adjust the position of the support rod and make the discharge door tightly closed

 